Stainless steel optical pedestrian smart swing barrier gate turnstile access control
1.production photo
2.Technical Data
Technical Data | Unit | DB341 |
Passage width | mm | 600 |
Throughput rate | p/m | 35 |
Power supply | V(ac) | 220~240 |
Operational voltage | V(dc) | 24 |
Max power consumption | w | 32 |
Frequency | hz | 50~60 |
Prectection level | ip | 44 |
Working temperature | -25~+70 | |
Electro-magnetic drive | DC | |
Dimension excluding bars | mm | 1400*280x980 |
Net weight including bars | kg | 85 |
3.Metrial Processing
4.Pure Manual Welding
5.Pure manual finishing and wiring layout
6.Fixed Acrylic
7.Driver control board
1). The PCB board is developed by our company.2). The PCB board be processed by listed company .8.Testing
1). Check the wiring
When connected power debugging, please check the wiring diagram according to each parts of the line is connected
Note: protective earth wire of equipment must reliable grounding, otherwise don't allow debugging.
2). Function test
(1) Turnstile actually pick two way signal (come in and out ).
(2) if the installation has LED indicator light on the surface, if the control PCB board receive the legitimate signal , turnstile will have green arrows in the direction.
9.Package
10.Warnings
Before starting installation, you must pay attention to those notes
1). The product can only put into normal operation after a certified status check and functional adjustment
2). The product must be earthed, and an earth leakage breaker is necessary on the power supply.
3). The depth of buried PVC tube should be greater than 60mm, and the exposed height above the ground should be greater than 50mm. The exit mouth should be bending back to avoid water dipping inside the tube;
4). To install swing barrier, the right/left barriers of each passage should be at the same horizontal line;
5). For product used outdoor, a cement platform of a height of 100mm~200mm should be set up at the installation site of the product to counter humidity and a ceiling or a shading facility should be added to guard against rain and sun;
6). Do not permit children to play on or around a turnstile . If child want to go through the turnstile, the parents must look after them;
7). Do not change the original inside wiring.
8). Keep the automatic control (push-button , remote control , etc) out of the reach of children .The control system must be installed at a minimum height of 1.5mm the ground surface.
9). Please do not use the system when there is lightning, otherwise, the system may be damaged.
11.Maintance
1). It is forbidden for those non-specialists to open the cabinet to carry out adjustment, maintenance and service of the product.
2). The housing of the equipment is of a sub-polish stainless steel. It is required to clean regularly with soft cloth so as to keep a clean and polish surface. It is forbidden to clean the surface with a hard object, otherwise, the good looking appearance may be affected. It is also forbidden to wash it with water, otherwise, short circuit may occur in the electric control system and the equipment may be damaged.
3). It is required to check regularly the connection of various movement sections of the equipment to avoid loosen fasteners, otherwise, turnstile failure may be resulted due to long term operation.
4). It is required to apply lubricant regularly to the movement sections.
5). It is required to check regularly the connection socket and connectors of the lines to ensure a reliable connection.
6). It is required to check regularly the protection grounding of the system to ensure a reliable connection.
7). It is required to recover the protection housing of the circuit and close properly the cabinet door after checking and maintaining properly the product.
12. Certification
13.FQA
Q:The Indicator lamp does not illuminate
A: Check the power supply and fuse
Q: Tripod permanently locked
A: Check the control board
Check the driving board.
Check the screws of the solenoid.
Q: The tripod jingles noisily when in operation.
A: Adjust the screws of buffer
Q: There is a hum when the tripod is in operation
A:Adjust the four screws of the solenoid to shorten the space.